Last Modified: 11-29-2007 |
1.6 A |
|
Service Category: Power Source/Network |
Section: Battery/Charging |
|
Model Year: 2008 |
Model: Sequoia |
Doc ID: RM000002BS400PX |
|
Title: 2UZ-FE BATTERY / CHARGING: GENERATOR: REMOVAL (2008 Sequoia) |
REMOVAL
1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
CAUTION:
Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.
NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected
.
2. REMOVE NO. 1 ENGINE UNDER COVER SUB-ASSEMBLY
3. REMOVE THROTTLE BODY COVER SUB-ASSEMBLY
4. REMOVE AIR CLEANER HOSE ASSEMBLY
5. REMOVE FAN AND GENERATOR V BELT
6. DISCONNECT VANE PUMP ASSEMBLY
7. REMOVE GENERATOR ASSEMBLY
|
(a) Disconnect the generator assembly connector.
|
(b) Remove the terminal cap and nut, and disconnect the generator wire.
(c) Remove the bolt and disconnect the wire harness bracket from the generator assembly.
|
(d) Remove the bolt, 2 nuts and generator assembly.
|
|